First aid injury: Person scalded by steam condensate

  • Safety Flash
  • Published on 20 December 2016
  • Generated on 1 April 2026
  • IMCA SF 35/16
  • 2 minute read

A Member has reported an incident in which a person was scalded when working in the kitchen/pantry area on-board a vessel.

What happened?

The incident occurred when the injured person was rinsing dishes in the ships pantry, near a boiler. The boiler exhausted steam through a vent pipe, and so a plastic tube was retro-fitted to the vent, allowing any condensate to drain into the sink in which the dishes were rinsed. Steam vented from the boiler and the condensate ran down the tube, exiting the pipe in to the sink and coming in to contact with the injured person’s right forearm. He immediately ran cold water over his arm and reported directly to the medic who carried out first aid.

vent tube

Vent tube

Exit to sink

Exit to sink

The injury

The injury

This photo may show graphic content.

The permanent solution

The permanent solution

Our member’s investigation noted the following:

  • The immediate response of applying cold water & seeking medical aid was correct & timely, preventing the injury from getting worse and avoiding potential subsequent infection.
  • Following the incident, the water boiler was immediately decommissioned until the correct means of venting steam/condensate had been established.
  • Vessel crew contacted the boiler manufacturer to seek guidance on correct solution. The manufacturer responded and supported installation of a permanent solution, to drain condensate directly into the main plumbing and away from the sink. This actively removed exposure to the hazard of hot steam/condensate.

Our member drew the following lessons from the incident:

  • Be aware of temporary solutions – the fitting of the plastic pipe should only have been considered as an initial temporary solution and should have been followed up with subsequent action to make a safer, permanent solution.
  • Ensure control measures don’t actually increase risk – the plastic pipe was installed as a control measure to reduce the risk presented by steam venting directly from the boiler. Whilst this solution was implemented with the best intentions, it reduced one risk but created another – that of draining hot condensate into the sink.
  • Report hazards & unsafe conditions – this boiler was installed six months before but no-one had raised any safety observations or reported any concerns until someone got hurt.
  • Stop work- regardless of your rank or role, or where you work on the vessel, be aware of unsafe acts and/or working conditions and exercise the stop work authority to ensure that they are corrected before anyone gets hurt.

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.