Cutting torch hose separates from flame arrestor

  • Safety Flash
  • Published on 4 June 2014
  • Generated on 12 December 2025
  • IMCA SF 08/14
  • 2 minute read

An incident has come to IMCA’s attention in which an Oxy-Acetylene cutting torch hose separated from the flame arrestor, resulting in a flashback.

What happened?

The incident occurred during welding modification of stabbing guides inside a pile driving hammer. While cutting a steel plate with a torch, the pipefitter experienced a flashback of flames as the connection of the hose suddenly came loose. Immediately the fire watch used the standby fire extinguisher and put out the flames. The men stopped the job and called for the supervisor. The pipefitter was unharmed and no property damage occurred.

The investigation revealed the following:

  • Immediate cause: was identified as inadequate repair using unsuitable techniques and methods. The inside diameter of the hose was larger than the one suited for this type/size of nipple so tape was used to make up the difference. The clamp could not tighten against the barb on the nipple and when the tape warmed up the hose and clamp slipped off over the barbed end.
  • Root Cause: was use of miss-matched materials that were inadequate for the task. The correct size hoses with clamps were ordered but were unavailable at the time. An improvised repair was made using tape to secure a tight fit.

Our member took the following corrective actions:

  • Inspect all torch hoses and remove all with this type of improvised connection.
  • Crew trained and provided awareness in proper materials and procedure.
  • A ‘safety stand down’ was conducted on-board to reiterate the importance of pre-job inspection and carrying out the job using the safest methods and materials.

Safety incidents involving pressurised gas fittings, oxy-acetylene cutting equipment and gas cutting in general are quite commonplace.

Latest Safety Flashes:

Vessel ran aground

A vessel on a short voyage ran aground while navigating through a narrow channel at low tide.

Read more
Fire in the engine room – fuel spray fire

A fire broke out on the starboard main engine due to a leak from the fuel pipe connection.

Read more
Fire hazard: missing splash tapes on fuel hose connections

It was observed that several engine fuel hose connections were not fitted with splash tapes.

Read more
Dropped pallet during cargo transfer

A plastic pallet loaded with plastic lube oil drums fell while being hoisted.

Read more
Positive – Enhancing safety communication through digital monitors

All crew and office personnel have 24/7 access to essential safety and operational updates.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.