Cutting torch hose separates from flame arrestor

  • Safety Flash
  • Published on 4 June 2014
  • Generated on 5 April 2026
  • IMCA SF 08/14
  • 2 minute read

An incident has come to IMCA’s attention in which an Oxy-Acetylene cutting torch hose separated from the flame arrestor, resulting in a flashback.

What happened?

The incident occurred during welding modification of stabbing guides inside a pile driving hammer. While cutting a steel plate with a torch, the pipefitter experienced a flashback of flames as the connection of the hose suddenly came loose. Immediately the fire watch used the standby fire extinguisher and put out the flames. The men stopped the job and called for the supervisor. The pipefitter was unharmed and no property damage occurred.

The investigation revealed the following:

  • Immediate cause: was identified as inadequate repair using unsuitable techniques and methods. The inside diameter of the hose was larger than the one suited for this type/size of nipple so tape was used to make up the difference. The clamp could not tighten against the barb on the nipple and when the tape warmed up the hose and clamp slipped off over the barbed end.
  • Root Cause: was use of miss-matched materials that were inadequate for the task. The correct size hoses with clamps were ordered but were unavailable at the time. An improvised repair was made using tape to secure a tight fit.

Our member took the following corrective actions:

  • Inspect all torch hoses and remove all with this type of improvised connection.
  • Crew trained and provided awareness in proper materials and procedure.
  • A ‘safety stand down’ was conducted on-board to reiterate the importance of pre-job inspection and carrying out the job using the safest methods and materials.

Safety incidents involving pressurised gas fittings, oxy-acetylene cutting equipment and gas cutting in general are quite commonplace.

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.