Skip to content

Electrical fault causes loss of thruster – DP undesired event

Comments from the report:
One of the three frequency converters on the port azimuth thruster was found to be burnt out.  Initial actions:

  •  The thruster was isolated and faulty converter dismantled.
  • Under the instructions from the manufacturer, the thruster was set up to work up to a maximum of 60% of the load.
  • The activity specific operating guidelines (ASOG) was revised to reflect the new power limits on the main propulsions.

Considerations of the IMCA Marine DP Committee from the above event:

  • The DP Yellow Alert should be initiated
  • The vessel had lost redundancy, but was not losing position.  It is highly likely the damage caused by the burnt-out converter would have been visible, so thruster 6 should have been checked prior to restarting.
  • The best policy is often to take time and assess the situation prior to attempting a restart.
  • Reducing the maximum power available from one azimuth thruster to 60% would require the capability plots to be revised in order to reflect this limitation in post failure position keeping ability.  It is assumed that appropriate DP capability plots were produced to support the revision in the ASOG.

The following case studies and observations have been compiled from information received by IMCA. All vessel, client, and operational data has been removed from the narrative to ensure anonymity.

Case studies are not intended as guidance on the safe conduct of operations, but rather to assist vessel managers, DP operators and DP technical crew in appropriately determining how to safely conduct their own operations. Any queries should be directed to IMCA at [email protected]. Members and non-members alike are welcome to contact IMCA if they have experienced DP events which can be shared anonymously with the DP industry.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.