- Registration open for IMCA Lifting & Rigging Seminar 2023
- Register for IMCA DP Conference 2023
- Check out our events calendar and meet with us at industry events
- Register to attend our Safety Seminar in June 2023
- Window for submission of IMCA Contractor Members Safety Statistics is now open
- See IMCA in action
Fatal Traffic Accident on Board a Large Vessel
What happened?
A member reported a fatal incident which occurred on a large Ro-Ro vessel during loading operations. A trailer loaded with two large wooden boxes drove down the ramp to deck number one and parked shortly after clearing the ramp on the port side of the cargo hold. With guidance from the stevedore foreman, the wooden boxes were unloaded by a forklift. When the unloading was finalised, the trailer reversed back up the ramp to deck two and hit the duty officer currently observing the cargo operations. The duty officer received medical assistance from shore very quickly, but unfortunately died in the ambulance on the way to hospital.
What went wrong?
Our member made the following findings:
- No one witnessed the trailer hitting the duty officer;
- The site of the accident is in a blind spot for the CCTV cameras;
- The noise level on the cargo decks on this kind of large vessel during loading and discharging is rather high, particularly on cargo deck one. It is not clear that an audible reversing alarm would have changed the outcome in this case;
- There was no indication that the duty officer was standing outside the yellow safety zone on the ramp when he was hit by the trailer;
- The duty officer was not wearing his safety helmet as was required. Based on his injuries, the assumption was made that he was hit by the trailer when he was looking up towards deck two;
- The driver of the trailer did not use any signal man/reversing assistant, nor did he look backward through his trailer window before starting to reverse;
- Criminal proceedings in the country in which this incident occurred resulted in:
- the driver of the trailer being prosecuted for negligent driving and sent to prison for 10 months
- the Stevedore foreman and the head of the stevedore contractor were both fined.
What were the causes?
- The immediate causes were found to be:
- the trailer driver failed to ensure that there were no obstructions when starting to reverse
- driver did not use a signal man/reversing assistant when reversing, even though he was driving a heavy vehicle;
- A causal factor was inadequate supervision/planning – the requirement to use a signal man/reversing assistant when reversing larger vehicles and trailers on board was not followed;
- The root cause of the incident was found to be an inadequate management system, which was not strict enough. The sub-contracted stevedore company did not ensure that the owners’ cargo handling instructions were followed.
What actions were taken? What lessons were learned?
- Better situational awareness is required, particularly in the cargo holds, during cargo operations, and anywhere were vehicles are working;
- A strengthening of PPE requirements particularly for high visibility clothing. Vessel management teams to ensure that existing requirements for hard hat or safety helmet is always complied with;
- A better awareness should be developed of control measures for non-routine operations.
Members may wish to review the following incidents:
Safety Event
Published: 25 September 2018
Download: IMCA SF 22/18
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.